TRUESITE WORKSTATION FOR FIRE COMMAND CENTER

  • Simplex fire alarm network connected graphical interface control.
  • Internet-based communications link enables facility managers and building owners to use computers and mobile devices to monitor the status of their entire fire alarm system network.
  • An Open Architecture Solution for Experienced Software Developers. Allows an Experienced 3rd Party Developer to create Custom 3rd Party Client Applications for Accessing Data, Informa tion, and/or Real-Time Events from the TSW
  • Available TCP/IP, LAN/WAN connections; up to 20 remote clients can be connected to the server for multiple remote users; with dedicated and listed Fire Alarm LAN equipment, listed remote clients can have control access.
  • Color graphical annunciation and control capacity for up to 62,500 points or point lists and 687 Nodes
  • TrueSite Workstation Mobile Client allows compatible iOS mobile devices to access system information, enables an iPhone, iPad, or iPod touch mobile device to become a TSW Mobile Client providing fire alarm network annunciation access with restricted features similar to a PC based Remote Client.
  • Email generation is available to send updates to individuals or to distribution lists with selectable content
  • Operates on Windows 7 Professional or Windows 7 Enterprise, 32-bit operation (remote client software is also compatible with 64-bit operation)

TRUE ALERT ES ADDRESSABLE MULTITONE HORN STROBE

Individually addressed and Controlled Multitone and Multi-Candela True Alert ES

  • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, 110, 135, or 185 cd
  • Per appliance tone selection of: 520 Hz Horn (Compliant to NFPA 72-2013), Broad band Horn, Bell, Chime, High/Low, Slow Whoop, or Siren, programmable from the control panel, or selected using an on-board DIP Switch. Hi or Low tone output also available.
  • TrueAlert ES appliances feature built in light and sound sensors to detect the opera tion of the strobe and sounder and confirm whether the strobe and sounder operat ed during testing
  • Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel. Results are viewable at the front panel display and printed reports can be generated from the panel service port.I
  • nstallation, When Class B wiring is used, wiring can be “T” tapped, allowing more savings in distance, wire, conduit, and overall installation efficiency.

FIRE ALARM CONTROL PANEL 4100 ES

  • Dual Configuration program CPU, convenient service port access, and capacity for up to 2500 addressable points
  • CPU Assembly includes 2GB dedicated compact flash memory for on-site system programing and information storage
  • 250 point addressable device IDNet 2 SLC that support TrueAlarm analog sensors and IDNet Comunications monitoring and control devices with an electrically isolated output channel allowing use with either shielded or unshielded, twisted or untwisted single pair wiring (Total 250 points for any combination Detectors and Modules)
  • Flexible, programmable switches Operators have simple, one touch control over critical system functions such as elevators and fans, and allow critical messages to be launched with the push of a button.
  • Integrated Audio Communication The 4100ES supports up to eight channels of digitized voice allow simultaneous and uniquel messages to be broadcast to different areas of a facility.
  • Remote Download and Programming When you connect your panels to the facility LAN, technicians can access and program them all from a central location. Decrease download times and avoid the need to escort technicians to sensitive areas of a facility.
  • Built In – IDNAC SLC that support Addressable Notification Appli ances that includes True Alert ES Visible Only (Strobe), Audible Only or Multitone Horn & Strobe. The Fire Alarm Control Panel monitors and records each addressable notification appliance status, type of appliance and each of configured appliance settings and automatic self test. Any fault in individual appliance will be reported as trouble condition to the control panel.
  • Backward compatibility is a major part of Simplex product design

FIRE ALARM CONTROL PANEL 4700 ES HYBRID / IDNAC

  • Flexible standard combination of conventional and addressable initiation satisfies a wide variety of new and retrofit applications.
  • 4007ES Hybrid supports both addressable and conventional detectors with wiring flexibility
  • Panels are ideal for buildings up to 250 points, expandable up to 3 isolated loops, Expandable from 8 to 32 Conventional Zones
  • 4.3 Inch Color Touch Screen Display
  • Simultaneously supports both conventional and addressable sensors,
  • Compatible with sensors
  • Compatible with True Alert ES Addressable Notification Appliances
  • USB port for uploading/downloading programs, software and reports • Compact design for small enclosures / spaces

ARRAY BASED INFRARED FLAME DETECTOR

Flamevision FV311SC

Features:

  • Built-in CCTV option to assist with rapid response
  • Fast, reliable flame detection using infra red detector
  • 256 infra red sensor array monitoring the field of view to separately indentify flame and non flame sources.
The FlameVision detector utilises infra red array based flame detection combined with integral CCTV to automatically and reliably indentify flame incidents and pin point the location on a video image.

The FLAMEVision offers a major improvement in both flame detection capability and immunity to false alarm sources over triple IR detectors.

Systern interface

  • RS485 serial data port suitable for network connection using a MODBUS protocol.
  • Video output compatible with twisted pair video cable.

Certified:
ATEX code: II 2 G Cenelec code: EEx d IIC T4 (-40°C to +80°C) and T5 (-40°C to + 65°C) Under ATEX certificate number Baseefa04ATEX0176X. This certification shows the FLAMEVI sion detectors are certified ‘flameproof, meeting the requirements of EN50014 and EN 540018

Enclosure :
Stainless Steel 316L
ANC4BFCLC to BS 3146 : Part 2

Detection Windows:
Sapphire

Relative Humidity :
Up 99% (non condesing)

Eclosure Protection:
Tested to IP66 an IP67
 

LINEAR HEAT DETECTOR

The Linear Heat Detection (LHD) cable is a combination of advanced polymer and digital technologies which can be used on any panel, and can detect heat anywhere along its entire length.

Typical Applications:

  • Rack Storage
  • Bulk Storage
  • Conveyors

  • Cable Trays
  • Fuel Storage Tanks
  • Elevator Shafts

  • Off Shore Paltforms
  • Pipelines
  • Engine Compartments

Temperature Rating:

155°F (68°C) (typical temperature), 172°F (78°C), 190°F (88°C), 220°F (105°C).